Specifications
Maximum Inlet Pressure: 3000 psig
Inlet Pressure Gauge (dual scale):
0–4000 psig/0–275 bar
Delivery Pressure Range
Delivery Pressure Gauge
Gauge Size: 2" Dial
Operating Temperature Range:
Regulators with Flowmeters:
32°F to 165°F
Regulators without Flowmeters:
-40°F to 165°F
Flow Coefficient:
Regulator: Cv = 0.15
Outlet Valve: Cv = 0.4
Inlet Connection: CGA 296, 320, 326, 346,
350, 540, 580, 590 or 660 as ordered
Outlet Connection:
1/4" NPT male (on outlet valve)
1/8" NPT female (on flowmeter)
Optional Relief Valve Vent Connection:
1/4" NPT male
Supply Pressure Effect: 0.04 psi per 100 psi
Approximate Weight: 5 lbs |
Materials of Construction
Body: Brass Forging
Outlet Valve and Gauges: Brass
Bonnet: Painted Zinc
Other Metal Parts Exposed to Gas:
Brass and Stainless Steel
Seat and Seals: Teflon®
Diaphragm: Neoprene
Flowmeter: Series 50 Flowmeter, Model FM4350
Optional Equipment
| Equipment |
Part No. |
| Relief Valves: |
|
| for TSD-15 |
RV5572-25i |
| for TSD-50 and TSD-750 Series |
RV5572-60i |
| for TSD-125 |
RV5572-140i |
| for TSD-250 |
RV5572-300i |
Table I, Regulators with Metering Valves
| |
Delivery Pressure |
Part No
Model SSD |
Range
(psig) |
Gauge
(psig) |
(dual scale)
(bar) |
| TSD-15-(CGA) |
2–15 |
0–30 |
0–2 |
| TSD-50-(CGA) |
4–50 |
0–60 |
0–4 |
| TSD-125-(CGA) |
10–125 |
0–150 |
0–10 |
| TSD-250-(CGA) |
20–250 |
0–400 |
0–27 |
|